Ann Vasc Surg ; 79: 439.e1-439.e5, 2022 Feb.
Article in English | MEDLINE | ID: mdl-34655749

ABSTRACT

We report of a patient with abdominal aortic aneurysm and renal transplant who underwent aneurysm repair. These patients can be treated by eather open or endovascular approach, depending on several factors, including aneurysm morphologic suitability for endovascular tretament, age of patient, and comorbidities.The main challange with open repair approach is to maintain renal transplant perfusion during the aortic cross clamping. Several methods of renal transplant perfusion during aneurysm repair have been described. In this case, we opted for open aneurysm repair beacuse of the age of the patient. The femoral venoarterial perfusion technique using extracorporal circulation machine was employed. We found this technique safe and easy in treating such patients.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation , Extracorporeal Circulation , Femoral Artery , Femoral Vein , Kidney Transplantation , Perfusion , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/physiopathology , Constriction , Femoral Artery/diagnostic imaging , Femoral Artery/physiopathology , Femoral Vein/diagnostic imaging , Femoral Vein/physiopathology , Hemodynamics , Humans , Male , Middle Aged , Renal Circulation , Treatment Outcome